Section
|
Dimensions
|
Sectional Area
|
Weight
|
Moment of Inertia
|
Section Modulus
|
w
|
h
|
t
|
per pile
|
per pile
|
per wall width
|
per pile
|
per wall width
|
per pile
|
per wall width
|
mm
|
mm
|
mm
|
CM^2
|
kg/m
|
kg/m
|
cm^4
|
cm^4
|
cm^3
|
cm^3/m
|
in
|
in
|
in
|
in^2
|
lbs/ft
|
lbs/ft
|
in^4
|
in/ft
|
in^3
|
in^3/ft
|
SP - III
|
400.0
|
125.00
|
13.000
|
76.42
|
60.0
|
150.0
|
2,220.0
|
16,800
|
223.0
|
1,340.0
|
15.7
|
4.92
|
0.152
|
11.85
|
40.3
|
30.7
|
53.3
|
123
|
13.6
|
24.9
|
SP - IV
|
400.0
|
170.0
|
15.500
|
96.99
|
76.1
|
190.0
|
4,670.0
|
38,600
|
362.0
|
2,270.0
|
15.7
|
6.69
|
0.610
|
15.03
|
51.1
|
38.9
|
112.0
|
283
|
22.1
|
42.2
|
Note :
| - Weight per linear length of wall is rounded off using the JIS Z 8401 - specified formula : [Weight per section / w (effective width) ] x 1000 - The inch sizes printed in highlight area are converted from metric sizes for you reference - The Hot - rolled section listed in this table are rolled at specific intervals deternined . Contact us for product availability, rolling frequency and pertinent information. - Materials under TIS compulsory standard are for domestis use only, while materials under other standards are for exportation. |
|
|
| |